Passive fire protection,Loughton, Essex

Fire-stopping you can prove.

We seal penetrations and linear gaps to the tested detail and, as standard, photograph, pin and log each one. When someone asks how a seal was made, the evidence is already on file.

Main contractors and housing providers

Fig. 01From our door to the CityNot to scale
  • CertificationAP4414FIRAS certificatedPenetration Sealing
  • Health and safetyNo. 181432CHAS EliteSSIP recognised
  • Supply chainReg. 1432425Constructionline GoldSupplier prequalification
  • Based inIG10 3TQLoughton, EssexLondon and the South East

01How we work

Survey, seal, record, hand over

One thread, from survey to handover.

Once the boards go on, a seal is out of sight. So as standard each seal goes through the same four steps, and each step leaves something you can check later.

  1. 1.1Survey

    We walk the compartment line with your drawings and drop a pin on each penetration and gap we find, so each seal has an address on the drawing.

    Leaves
    A pinned drawing
    Part plan of level 03, marked up as a fire-stopping survey. Ten pins sit on the penetrations in the compartment line, the corridor and the riser. Pin P-02 is selected: cables, a steel pipe and a plastic pipe through the compartment wall, with a photo sketch and the measured opening. 3 4 5 C D 5060 1410 3530 2000 5000 3825 FLAT 03.01 FLAT 03.02 FLAT 03.03 STAIR LIFT STORE RISER FIRE DOOR CABLE TRAY P-01 P-03 P-04 P-05 P-06 P-07 P-08 P-09 P-10 P-02 MIXEDPHOTO 1 OPENING 300 x 300 PIPE STEEL 54 PIPE PLASTIC 110 CABLES 5 PART PLAN, LEVEL 03 0 1 2 3 4 5 M KEY PLAN REV DATE NOTE A 05.10.26 SURVEY SELECTED DEFECT FOUND COMPARTMENT LINE TO INSPECT SEALED BLOCKWORK CEILING VOID CABLE TRAY STUD WALL 1 2 3 4 5 P-10 P-05 P-06 P-07 P-03 P-04 SELECTED DEFECT FOUND TO INSPECT SEALED
    1. Pin P-02, mixed services through the wall: opening 300 x 300, steel pipe 54, plastic pipe 110, 5 cables
    2. Fire door
    3. Riser
    4. Compartment line
    5. Cable tray over
    Fig.02TitleSurvey pin, level 03ViewPlanStatusIllustration
  2. 1.2Seal

    Each seal goes in to the tested detail specified for that wall or floor. We record the product used and who fitted it.

    Leaves
    A seal to the tested detail
    Detail sheet for a double coated batt seal in a fire-rated stud wall. Elevation: two batt layers stacked as one pattress, lapped onto the wall over the aperture, joints staggered and stitched with pigtail fixings, a steel pipe ringed in intumescent sealant, a cable bundle with batt coating carried along it, a copper pipe and a plastic pipe with a collar. Section A-A: two layers of board on each face, both batt layers stacked on the front face, the services passing through, a collar on each face of the batt and the coating run-back. Detail 1: the sealant bead where the batt meets the wall. ELEVATION SECTION A-A DETAIL 1X4 MIN SEP GAP FIRE-RATED WALL BATT OVERLAP ONTO WALL STEEL PIPE CABLES JOINTS STAGGERED COPPER PIPE PLASTIC PIPE COATING RUN-BACKPER THE TESTED DETAIL METAL STUD 2 LAYERS BOARD, EACH FACE SCHEDULE ACOATED BATT, 50 MM X 2 BINTUMESCENT SEALANT CPIPE COLLAR, EACH FACE DBATT COATING ON SERVICES EPIGTAIL FIXINGS ALL TO THE TESTED DETAIL A B AA A B B C D E A B C C D
    1. Coated batt, 50 mm x 2
    2. Intumescent sealant
    3. Pipe collar, each face
    4. Batt coating on services
    5. Pigtail fixings
    Fig.03TitleBatt and masticViewElevation, sectionStatusIllustration
  3. 1.3Record

    We photograph it before, during and after, pin it to the drawing and log it in Assaya, our own record app. Each entry is chained to the one before, so any later change shows.

    Leaves
    Three photos and a chained record
    P-02Seal recordLogged in AssayaEntry 0412Sample
    P-02L03 C408:41L03 C408:41
    01BeforeAs found
    P-02L03 C410:22L03 C410:22
    02DuringFirst layer, bead
    P-02L03 C413:05L03 C413:05
    03AfterSealed, labelled
    PinLevel 03 plan, grid C4

    Seal IDP-02L03 C4Entry 0412

    IDLabel by the seal
    Ref
    P-02
    Work type
    Double pattress seal
    Services
    Cables, steel pipe, plastic pipe
    Size
    300 x 300 mm
    Products
    • Coated battBatch B-0000
    • Intumescent sealantBatch B-0000
    • Pipe collarBatch B-0000
    Detail ref
    Tested detail ref
    Rating
    EI 60 (required)
    Installer
    Operative signed 13:12
    Inspected by
    Supervisor signed 13:19
    Recorded
    14 Oct 2026, 13:21
    Prev hash
    9F2C 11A0
    Hash
    4272 79E0
    Status
    Recorded
    Chain ledger, last entries
    No.RefPinLoggedPrev hashHash
    0410P-04L03 D411:52A41E 7B036E09 A3F1
    0411P-01L03 C312:486E09 A3F19F2C 11A0
    0412P-02L03 C413:219F2C 11A04272 79E0
    0413---4272 79E0Chains here
    Fig.04TitleSeal record, pin P-02SourceAssayaStatusSample
  4. 1.4Hand over

    You receive a register the building keeps: drawings, pins, photos and data sheets in one pack, built to support golden-thread record keeping. Yours, not ours.

    Leaves
    The register
    PASSIVE FIRE PROTECTION
    HANDOVER PACKSAMPLE

    Handover pack

    Operation and maintenance file

    Sample QR label

    Project
    Sample project
    Rev
    B
    Client
    Main contractor
    Date
    23.10.2026
    Document
    Fire stopping record
    Pages
    48
    Prepared by
    Rockfirepro Ltd

    ContentsPage

    1. 1Schedule of works2
    2. 2Seal records6
    3. 3Photo appendix14
    4. 4Product data sheets22
    5. 5Certificates and test evidence31
    6. 6Drawings with pins40

    Rockfirepro Ltdrockfirepro.co.ukPage 1 of 48

    Fig.05TitleThe register you keepFormatHandover packStatusSample

02Services

Install, survey, record

Fitted to the detail. Recorded as we go.

We install to the tested detail in the specification, and we record each seal as it goes in.

  1. 2.1

    Penetration sealing

    FIRAS AP4414

    Pipes, cables and ducts through fire-rated walls and floors, sealed to the tested detail.

  2. 2.2

    Linear gap sealing

    FIRAS AP4414

    Head-of-wall, wall-to-wall and wall-to-floor gaps closed, so the compartment line runs unbroken.

  3. 2.3

    Fire compartmentation

    Breaches in compartment walls, floors and service voids made good.

  4. 2.4

    Intrusive surveys

    We open up ceiling voids, risers and cupboards and record what we find on the drawing, with photos.

  5. 2.5

    Cavity barriers

    Cavity barriers fitted to close concealed voids in ceilings, roofs and floors.

  6. 2.6

    Remediation works

    A defect list priced, worked through and closed out against its original reference, with before and after photos.

  7. 2.7

    Records and handover

    A seal-by-seal register with photos, pins and data sheets, handed over when the work is done.

FIRAS AP4414Our FIRAS certificate covers penetration sealing, including linear gap seals.

03Credentials

Certificates to view

Certificated, prequalified, registered.

Our FIRAS certificate and waste carrier registration link straight to the public registers. Click or tap a card to see the issued certificate.

3.1Third-party certification

FIRAS certificated

CertificateAP4414Issue 1

An independent body has assessed how we install penetration seals.

Scheme
FIRAS (Warringtonfire)
Issued by
Warringtonfire Testing and Certification Limited
Module
Penetration Sealing
Covers
Penetration seals and linear gap seals
From
Valid to

3.2Health and safety

CHAS Elite

Common Assessment Standard

Membership
181432
Certificate
691E0C3B-A383-48A4-BECD-01E3064319D0
Issued by
CHAS
Valid to

View certificate: CHAS Elite

3.6Cyber security

Cyber Essentials

Whole organisation

Certificate
978eba8f-b619-44de-9d46-e6958011647e
Issued by
IQ in IT for IASME
Certified
Recert. due

View certificate: Cyber Essentials

04About

Rockfirepro Ltd

Fire-stopping, from Loughton.

Rockfirepro Ltd is a fire-stopping contractor based in Loughton, Essex. We work for main contractors and housing providers across London and the South East, and we install to the tested detail in the specification.

Company sheet

4.1CompanyRockfirepro Ltd

Registered
England and Wales
Company no.
16969024Companies House
Office
Unit 4 York House
Langston Road
Loughton IG10 3TQ
Area
London and the South East
Clients
Main contractors and housing providers
Records
Assaya, our own record app

4.2What we doInstall, survey, record

  1. 2.1Penetration sealingFIRAS AP4414
  2. 2.2Linear gap sealingFIRAS AP4414
  3. 2.3Fire compartmentation
  4. 2.4Intrusive surveys
  5. 2.5Cavity barriers
  6. 2.6Remediation works
  7. 2.7Records and handover
Services in detail

4.3How we workSurvey, seal, record, hand over

As standard, each seal goes through the same four steps, and each step leaves something you can check later.

  1. 1.1SurveyLeavesA pinned drawing
  2. 1.2SealLeavesA seal to the tested detail
  3. 1.3RecordLeavesThree photos and a chained record
  4. 1.4Hand overLeavesThe register

05Contact

Phone, WhatsApp or email

Send us the drawings.

Tell us the building, where it is and roughly what needs sealing. Drawings or an existing survey help us price it properly.

We aim to respond to all enquiries within 1 business day.

Phone and WhatsApp
07432 588344
Call 07432 588344 WhatsApp 07432 588344 (opens WhatsApp)
Email
info@rockfirepro.co.uk
Email info@rockfirepro.co.uk
Office
Unit 4 York House
Langston Road
Loughton IG10 3TQ
Location plan, not to scale. Unit 4 York House is on Langston Road, Loughton. Langston Road runs east off Chigwell Lane, the A1168, past Epping Forest Shopping Park. Debden station on the Central line is to the west, and junction 5 of the M11 is to the south-west.
  1. Unit 4 York House, Langston Road, IG10 3TQ
  2. Debden station, Central line
  3. M11 junction 5, Chigwell Lane (A1168)
  4. Epping Forest Shopping Park

Plan drawn from OpenStreetMap data. Copyright OpenStreetMap contributors.

Fig.07TitleOur unit, LoughtonScaleNot to scale

Send an enquiry

A few details and your drawings are enough to start.

NotesWhat helps us price

  1. Building type, and whether the work is in walls or floors.
  2. Roughly how many penetrations.
  3. Drawings or an existing survey: PDF, DWG, DXF or images.
Your details
The site
Drawings
Drawings or photos
Send

This opens your email app with the details filled in, ready to send to info@rockfirepro.co.uk. Attach your drawings there.

We use your details only to answer your enquiry.Privacy notice (opens in a new tab)

No.
05
Sheet
Enquiry for pricing
To
Rockfirepro Ltd
Date
-
Status
Draft

Certificate

Certificate